Product Description
S31803 duplex butt-weld pipe fittings are wrought duplex stainless fittings in UNS S31803, the original 2205 grade also known as EN 1.4462. They are ordered to ASTM A815/A815M for the material and to ASME B16.9 for the outline, from NPS 1/2 through NPS 48. A butt-weld end becomes part of the pressure boundary, so the grade, the schedule, and the fitting class have to be fixed before the fitting is cut.
This is duplex 2205, not a super duplex grade. Super duplex is UNS S32750 (2507) or S32760. Calling S31803 "super duplex" orders the wrong alloy. UNS S32205 is the tighter 2205 analysis and can be dual-certified to S31803; an S31803 fitting does not automatically meet S32205. If the piping class asks for S32205, write that number on the enquiry.
Duplex 2205 is chosen where 304 or 316L would be short on strength or on chloride pitting and stress-corrosion resistance: seawater cooling, desalination, and chemical process lines. Resistance still depends on temperature, chloride level, and whether the weld was made and cooled correctly. It is not a rating for every chloride service.
Ordering Range
The sizes below are the standard ranges for the fitting, not a stock list. A fitting outside ASME B16.9, or a schedule the pipe standard does not define, is quoted from the drawing.
| Item | Reference | What to confirm |
|---|---|---|
| Standard butt-weld fittings | ASME B16.9, NPS 1/2 to NPS 48 (DN 15 to DN 1200) | NPS, end schedule, and fitting type |
| Light-wall corrosion fittings | MSS SP-43, NPS 1/2 to NPS 24, Schedule 5S and 10S, long radius | Do not substitute these for a B16.9 pressure fitting |
| Short-radius elbows and returns | Now covered by ASME B16.9 | ASME B16.28-1994 was withdrawn into B16.9 |
| Weld ends | ASME B16.25 | Bevel, root face, and unequal-wall transition |
| Above NPS 48 | Not an ASME B16.9 catalogue size | Drawing only; do not extend the old 48 in. line |
Chemical Composition
The ranges below are the UNS reference analyses for 2205, not a fitting heat analysis and not a guaranteed ladle analysis of every fitting on this page. S32205 sits inside S31803 but raises the floor on chromium, molybdenum, and nitrogen. The two rows must not be merged into one "2205" line.
| Element | UNS S31803 | UNS S32205 |
|---|---|---|
| Carbon | 0.030 max | 0.030 max |
| Manganese | 2.00 max | 2.00 max |
| Silicon | 1.00 max | 1.00 max |
| Phosphorus | 0.030 max | 0.030 max |
| Sulfur | 0.020 max | 0.020 max |
| Chromium | 21.0–23.0 | 22.0–23.0 |
| Nickel | 4.5–6.5 | 4.5–6.5 |
| Molybdenum | 2.5–3.5 | 3.0–3.5 |
| Nitrogen | 0.08–0.20 | 0.14–0.20 |
A supplier table that prints chromium 22.0–23.0 on the S31803 row and 21.0–23.0 on the S32205 row has the two grades reversed. A nitrogen range of 0.8–2.0, or a single merged row, is the same class of error. Reject that sheet and match the heat to the UNS number on the order.
Mechanical Properties
ASTM A815 sends the mechanical requirements back to the pipe specification the fitting is made from. For duplex 2205 that is ASTM A790/A790M. The figures below are those pipe minimums, published as a grade reference. They are not a tested value for every fitting, and they are not a design allowable.
| Property | S31803 | S32205 |
|---|---|---|
| Tensile strength, min | 620 MPa (90 ksi) | 655 MPa (95 ksi) |
| Yield strength, 0.2% offset, min | 450 MPa (65 ksi) | 450 MPa (65 ksi) |
| Elongation in 2 in. (50 mm), min | 25% | 25% |
An older page on this item quoted one set of figures for both grades: 795 MPa tensile, 550 MPa yield, and 25% elongation. Those numbers are not the A790 minimums. S32205 is only 35 MPa above S31803 in tensile strength, and the yield floor is the same 450 MPa. Hardness is not published here. A815 does not set one hardness cap that every schedule can be sold against, and the 31 HRC figure circulated for 2205 plate is a different product form.
Duplex 2205 is not a high-temperature alloy. Sigma and related phases precipitate with time above about 300 °C (570 °F), and impact toughness falls sharply at sub-zero temperature. The continuous-service window is −40 °C to 280 °C. Give the design temperature and the piping code on the enquiry when the duty sits outside that window.
Material Characteristics
In the solution-annealed condition, 2205 is about half ferrite and half austenite. That balance is why the 450 MPa yield floor on this page is above the 170 MPa WP316L floor printed on the 2 inch stainless fittings page, and why chloride stress-corrosion resistance is better than a standard austenitic grade. The balance is also why the fitting has to be cooled correctly after annealing. Slow cooling through about 700–950 °C lets sigma phase form, which cuts toughness and corrosion resistance.
ASTM A815 uses the same class letters as ASTM A403. WP fittings follow an ASME or MSS dimensional standard. CR fittings follow MSS SP-43, have no class letter, and are not given the NDE of a WP class.
| Mark | Construction | Examination |
|---|---|---|
| WP-S | Seamless, no weld seam | No radiographic or ultrasonic class |
| WP-W | Welded from tested pipe, filler welds radiographed | Radiography of the fitting welds that added filler metal |
| WP-WX | Welded, all welds radiographed | Radiography of all welds |
| WP-WU | Welded, all welds ultrasonic | Ultrasonic examination of all welds |
| CR | MSS SP-43 light-wall only | No WP class and no NDE class |
Welding uses a 2205 consumable such as ER2209, with heat input and interpass temperature held so the weld metal stays near the 40–60% ferrite window. There is no filler that turns an S31803 fitting into S32750. Flanges in this family are forged to ASTM A182 F51 (S31803) or F60 (S32205) and are not butt-weld fittings; see the duplex 2205 flanges and the S31803 blind flange.
Applications
Typical service is chloride-bearing process piping where a 300-series austenitic fitting is marginal: seawater and brackish cooling water, desalination, pulp bleaching, and chemical lines that see chlorides with moderate temperature. The fitting is also used where the higher yield strength lets the designer drop a schedule, provided the piping code allows it.
Do not use this page for super duplex seawater systems that specify S32750 or S32760, for forged flanges and threaded fittings, or for sour service unless the order states the NACE MR0175 / ISO 15156 conditions. A fitting has no pressure class of its own. Class 150, 300, 600, and 900 are flange ratings and do not belong on a butt-weld elbow, tee, reducer, or cap. The allowable pressure is calculated from the matching pipe, the code, and the temperature.
The duplex stainless steel pipe fittings category covers the wider duplex range. Plate and coil in the same 2205 family are separate products: duplex stainless steel plate and sheet and 2205 duplex stainless steel coil. Austenitic butt-weld fittings, including 316L and 317L, are listed under stainless steel butt-weld fittings.
Ordering Information
Send the UNS number (S31803 or S32205), the fitting type and angle, NPS of each end, the schedule or wall of each end, and the class (WP-S, WP-W, WP-WX, WP-WU, or CR). Add the dimensional standard, the weld-end preparation, quantity, and whether an EN 10204 3.1 certificate is required. For corrosion service, also send the fluid, chloride level, and design temperature so the grade can be checked before the fitting is made.
Is S31803 a super duplex fitting?
No. S31803 is duplex 2205. Super duplex is S32750 or S32760, with higher chromium, molybdenum, and nitrogen. The two families are not substitutes. If the line class says 2507, this fitting is the wrong grade.
Does an S31803 fitting meet S32205?
Not by itself. S32205 has a higher minimum chromium, molybdenum, and nitrogen than S31803, and its pipe tensile minimum is 655 MPa rather than 620 MPa. A heat can be dual-certified only when it meets the tighter analysis. Ask for S32205 on the order when the specification requires it.
Which standard covers the fitting, ASTM A815 or ASME B16.9?
Both, for different things. ASTM A815/A815M is the material and testing standard. ASME B16.9 is the dimension standard from NPS 1/2 to NPS 48. MSS SP-43 covers light-wall Schedule 5S and 10S fittings only, through NPS 24. ASME B16.28 is not a current standard; short-radius elbows now sit in B16.9.
Can these fittings be ordered in Class 150 to Class 900?
No. Those classes are flange pressure ratings. A butt-weld fitting takes the wall of the pipe it is welded to. State NPS and schedule, not a flange class. Forged socket-weld and threaded fittings are a different product and use ASME B16.11.
What should be on the enquiry?
UNS number, fitting type, NPS and schedule of every end, WP or CR class, dimensional standard, quantity, certificate type, and the design temperature and fluid. Without the grade split and the class, the fitting cannot be matched to the line.