Skip to Content

Comparing Steel Grades Across Standards

James Blue, Piping Materials Specialist

Comparing Steel Grades Across Standards

A cross-standard grade comparison is a verification workflow, not a chart you read once and apply to every project. Two grades from two standard systems are only comparable once the standard edition, product form, delivery condition and test scope are fixed, because those are the items that move the numbers. A cross-reference name is a screening hint; the acceptance document is the material test report read against the edition named on the order.

Why an Equivalent Chart Cannot Be the Decision

Standard systems are written for different product forms, testing frequencies and supplementary requirement structures. Chemical limits, heat treatment and mandatory tests move independently of the grade name, so a chart row that matches one property says nothing about the others. It also cannot carry a commitment: a grade is certified against the standard it was produced and tested to, not against every requirement of a standard it was never ordered to.

The Comparison Workflow

  1. Fix the governing document: standard, edition, and any annex or supplementary requirement. Compare against it, not against a table found online.
  2. Fix the product form and manufacturing route; the same nominal grade has different supply conditions as pipe, plate, forging, fitting or fastener.
  3. Compare the property rows the design uses: yield and tensile minimums, any upper limit or maximum yield-to-tensile ratio, the elongation basis and specimen, impact test temperature with energy, and the delivery condition.
  4. Compare the inspection and document scope: product specification level, extent of nondestructive examination, hydrostatic testing and certificate type.
  5. Record the outcome in writing: either procure to the standard the design names, or obtain written approval from the responsible engineer supported by the comparison.

Steps three and four are where most substitutions fail, and a chart does not perform either step.

Worked Example 1: API 5L Grade B and ISO 3183 L245

This is the safest kind of comparison, because the two names sit inside one family rather than across two unrelated systems. API 5L Grade B carries the ISO 3183 name L245, and the number is the specified minimum yield strength: 245 MPa (35,500 psi) minimum yield, with 415 MPa (60,200 psi) minimum tensile on the seamless PSL1 reference envelope. The L number in MPa and the X number in ksi are two ways of writing the same yield requirement.

Even here the name alone is not the order. PSL1 and PSL2 are different quality levels; PSL2 adds upper strength limits, a maximum yield-to-tensile ratio of 0.93, mandatory Charpy V-notch testing, per-pipe NDE and hydrostatic testing, and the delivery condition suffix becomes part of the grade name. The reference envelope is on the API 5L Grade B seamless pipe page.

The same letter in another standard is not the same grade: API 5L Grade B is not ASTM A53 Grade B and not ASTM A106 Grade B, and a matching letter does not make them interchangeable on a design calculation. If the specification names one of the ASTM grades, send that standard with the enquiry; the seamless family requirements are grouped on the seamless carbon steel pipe page.

Worked Example 2: A105 and A350 LF2

ASTM A105 and ASTM A350 LF2 are the pair most often treated as interchangeable because their strength rows match. They are not, and the reason is not strength.

ItemA350 LF2A105
Tensile strength70 - 95 ksi [485 - 655 MPa]70 ksi [485 MPa] minimum
Yield strength, min36 ksi [250 MPa]36 ksi [250 MPa]
Impact testingMandatory Charpy V-notch, by classNot required unless named as a supplementary requirement
Heat treatmentNormalized, normalized and tempered, or quenched and temperedNot mandatory in every case; specified when the order or design condition calls for it

The strength rows are the same, so the row that decides the purchase is impact testing. LF2 cannot be released without Charpy V-notch results at the class test temperature, while A105 carries no impact requirement unless the purchaser writes one in. Substituting A105 for LF2 on a matching yield number removes the one property the low-temperature design was relying on.

A second trap sits inside LF2 itself: Class 1 and Class 2 are impact test conditions, not two strength levels. Class 1 is tested at -50 F [-46 C] with a minimum average absorbed energy of 15 ft-lbf [20 J] over three specimens; Class 2 at 0 F [-18 C] with a minimum average of 20 ft-lbf [27 J]. Both classes share the same 36 ksi [250 MPa] minimum yield, so a table showing a higher minimum yield for Class 2 describes another material. Full rows are on the ASTM A350 LF2 low-temperature carbon steel flange and ASTM A105 carbon steel flange pages.

What a Comparison Cannot Conclude

  • A matching yield strength does not make two grades equivalent.
  • A cross-reference in a supplier table is not a standard requirement and not an acceptance.
  • An older designation is not the current one; standards renumber grades.
  • A test report for one heat and one product form does not cover another form.
  • Procuring to the standard the design names remains the default; a substitution needs written approval from the responsible party.

What to Send with the Enquiry

Standard and edition, grade and any suffix, product form and route, dimensions, quantity, delivery condition, required tests and certificate type. Where a substitution is considered, send both standards with the design temperature, pressure and medium so the comparison is made against the two documents rather than a name.

Does an equivalent grade mean an identical material?

No. Equivalent charts are screening tools; chemistry and mechanical limits can still differ by standard.

What should be approved for purchase?

Approve the exact standard and grade required by the design, not only a cross-reference description.

Frequently Asked Questions

Does an equivalent grade mean an identical material?

No. Equivalent charts are screening tools; chemistry and mechanical limits can still differ by standard.

What should be approved for purchase?

Approve the exact standard and grade required by the design, not only a cross-reference description.

Related Products