Product Description
API Spec 5DP S-135 drill pipe is the highest-strength drill pipe grade in common API 5DP service. One joint is an assembly: a seamless, heat-treated pipe body with upset ends plus two friction-welded tool joints. In the drill string it transmits rotary torque and tensile load, circulates drilling fluid and connects the rig equipment to the bottom-hole assembly. In the API 5DP grade system, S-135 is the commercial name of the "S" pipe-body grade in Grade Group 3 - 135 is the specified minimum yield strength in ksi (135,000 psi = 931 MPa), and the grade also carries a 145,000 psi (1000 MPa) minimum tensile requirement.
This page covers standard (non-sour) S-135 drill pipe in sizes from 2-3/8 in. to 6-5/8 in. OD, in R1, R2 and R3 lengths with NC, IF, FH or REG rotary shouldered connections. The sections below set out the grade system, the chemistry and mechanical requirements API 5DP actually imposes, tool-joint and weld-zone controls, PSL levels, and the details a complete enquiry should carry. Drill pipe is an oilfield drill-string tubular, not line pipe: pipe that transports fluid after it leaves the well is bought to API 5L - see our carbon steel line pipe page for that product family.
API 5DP Grade System and Where S-135 Sits
API 5DP identifies drill pipe body grades by a letter (the strength group) and a number (the specified minimum yield strength in thousands of psi). The letter also fixes the minimum tensile strength - a "G" grade always has a minimum tensile of 115 ksi, and grades such as "G-95" or "S-105" do not exist. X95, G105 and S135 form Grade Group 3 and are full-length quench-and-tempered after upsetting; E75 (Group 1) may be supplied normalized or normalized-and-tempered. The current edition also covers the V150 grade and the sulfide-stress-cracking-resistant SS75/SS95/SS105 grades.
The values below are the API 5DP tensile requirements for the drill pipe body (Table C.5 / D.5), shown in both customary and SI units.
| Grade | Grade group | Min yield | Max yield | Min tensile | Typical selection |
|---|---|---|---|---|---|
| E75 | 1 | 75,000 psi (517 MPa) | 105,000 psi (724 MPa) | 100,000 psi (689 MPa) | Shallow and standard wells |
| X95 | 3 | 95,000 psi (655 MPa) | 125,000 psi (862 MPa) | 105,000 psi (724 MPa) | Directional and mid-depth wells |
| G105 | 3 | 105,000 psi (724 MPa) | 135,000 psi (931 MPa) | 115,000 psi (793 MPa) | Deep wells, higher tensile load |
| S135 | 3 | 135,000 psi (931 MPa) | 165,000 psi (1138 MPa) | 145,000 psi (1000 MPa) | Deep, ultra-deep, ERD and high-torque drilling |
| V150 | - | 150,000 psi (1034 MPa) | 170,000 psi (1172 MPa) | 160,000 psi (1103 MPa) | Highest standard grade; order-specified |
Designations such as "R780" sometimes appear next to API grades in distributor listings. R780 is a geological and coal-mine drill rod grade (36Mn2V or 42MnMo7, around 780 MPa minimum tensile) that belongs to a different product family with its own Chinese standards - it is not an API 5DP drill pipe grade and should not be compared line-by-line with S-135.
Chemical Composition Requirements
Unlike casing and tubing standards, API 5DP is not a full-chemistry specification. It caps phosphorus and sulfur in the pipe body and tool joints and leaves the balance of the analysis to the manufacturer, who must use it to reach the mechanical properties. The standard additionally requires a fine austenitic grain structure, achieved with at least one grain-refining element (aluminium, niobium, vanadium or titanium) and confirmed after heat treatment.
The table below summarises the chemistry limits the standard does impose (API 5DP Table C.4 / D.4, maximum values in weight %).
| Product / grade group | P max | S max |
|---|---|---|
| Pipe body, Grade E75 | 0.030 | 0.020 |
| Pipe body, X95 / G105 / S135 / V150 | 0.020 | 0.015 |
| Pipe body and tool joints, SS75 / SS95 / SS105 | 0.015 | 0.010 |
| Tool joints, Grades E / X / G / S / V | 0.020 | 0.015 |
Some data sheets publish complete mill analyses for S-135 body steel - carbon, manganese, chromium, molybdenum and nickel additions selected for the strength-toughness combination. Treat those as typical manufacturer practice, not as API acceptance limits: two mills can meet the same S-135 requirement with different chemistries. Acceptance should rest on the mechanical and test requirements, with the mill certificate traceable to heat numbers.
Mechanical Requirements of the S-135 Pipe Body
The values below are the API 5DP acceptance requirements for the S-135 drill pipe body. They are minimums; the standard sets no maximum tensile strength for the standard grades.
| Property | S-135 requirement (pipe body) |
|---|---|
| Yield strength | 135,000 psi (931 MPa) minimum; 165,000 psi (1138 MPa) maximum |
| Tensile strength | 145,000 psi (1000 MPa) minimum |
| Elongation | Calculated from the tensile-test specimen cross-sectional area per the API 5DP elongation table (625,000 x A^0.2 / U^0.9), not a single fixed percentage |
| Charpy V-notch, PSL-1 | 21 +/-3 deg C: 54 J (40 ft-lbf) minimum average; 47 J (35 ft-lbf) minimum single value |
| Charpy V-notch, PSL-3 | -20 +/-3 deg C: 100 J minimum average; 80 J minimum single value |
| Weld zone hardness | 37 HRC maximum, surface and through-wall mean (Grades E, X, G and S; 40 HRC for Grade V) |
Two frequently copied figures deserve care. First, impact energy: several supplier pages quote "80 J average / 65 J single" as if it were the S-135 body requirement, but that pair matches subsize-specimen or other-specification rows; the API 5DP PSL-1 body requirement is 54 J / 47 J at room temperature, and the lower-temperature values apply only when PSL-3 or the relevant supplementary requirements are ordered. Always ask which specimen size, temperature and component (body, weld zone or tool joint) a quoted energy value refers to.
Second, hardness. Older listings often show "HRC 28-36" as an S-135 steel property. That band is not a pipe body requirement. Tool joint material hardness is stated separately as 285-341 HBW. API 5DP's hardness controls for standard grades focus on the weld zone (37 HRC maximum as above); it is the sour-service SS grades whose body hardness is directly capped - for example SS95 at 25.0 HRC average / 27.0 HRC single maximum through-wall.
Heat treatment is part of the requirement, not an option: Grade Group 3 grades (X95, G105, S135) must be full-length quench-and-tempered after the ends are upset, because upsetting re-introduces local transformation risk at the transition. A furnace batch record traceable to heat and lot numbers is the document that lets a buyer verify this at receiving inspection.
Sizes, Upset Types and Rotary Shouldered Connections
API 5DP assigns the upset type and the standard connection for each size and nominal weight. The combinations below are the commonly ordered ones from the standard's dimension tables (wall thicknesses in inches, weights in lb/ft).
| OD (in.) | Nom. weight (lb/ft) | Wall (in.) | Upset | Connection |
|---|---|---|---|---|
| 2-3/8 | 6.65 | 0.280 | EU | NC26 |
| 2-7/8 | 10.40 | 0.362 | EU | NC31 |
| 3-1/2 | 13.30 | 0.368 | EU | NC38 |
| 3-1/2 | 15.50 | 0.449 | EU | NC38, NC40 |
| 4 | 14.00 | 0.330 | IU, EU | NC40, NC46 |
| 4-1/2 | 16.60 | 0.337 | EU, IEU | NC46, NC50 |
| 4-1/2 | 20.00 | 0.430 | EU, IEU | NC46, NC50 |
| 5 | 19.50 | 0.362 | IEU | NC50 or 5-1/2 FH |
| 5 | 25.60 | 0.500 | IEU | NC50 or 5-1/2 FH |
| 5-1/2 | 21.90 | 0.361 | IEU | 5-1/2 FH |
| 5-1/2 | 24.70 | 0.415 | IEU | 5-1/2 FH |
| 6-5/8 | 25.20 | 0.330 | IEU | 6-5/8 FH |
| 6-5/8 | 27.70 | 0.362 | IEU | 6-5/8 FH |
The three upset types change the pipe-end bore and the tool-joint transition: IU (internal upset) reduces the inside diameter at the end while keeping the outside diameter; EU (external upset) increases the outside diameter while keeping the bore; IEU (internal-external upset) does both, maximising the upset cross-section and connection fatigue resistance. Note that the upset type follows the size in the standard - IEU is the configuration for 5 in. and larger pipe, so an enquiry for "5 in. EU" or "5-1/2 in. EU" drill pipe is not a standard combination.
Connections are threaded and gauged to API Spec 7-2. The NC (numbered connection) series is the API-recommended standard with the V-0.038R rounded thread root, which carries better fatigue life than the legacy forms, and several NC sizes are dimensionally interchangeable with older IF and FH connections: NC26 = 2-3/8 in. IF, NC31 = 2-7/8 in. IF, NC38 = 3-1/2 in. IF, NC40 = 4 in. FH, NC46 = 4 in. IF and NC50 = 4-1/2 in. IF. Gauges interchange, but the thread form differs, so new strings should specify NC. IF connections have been phased out and FH survives mainly as 5-1/2 FH; REG remains in use chiefly for bottom-hole assembly components and bit boxes. All rotary shouldered connections seal metal-to-metal on the shoulder, and make-up torque values should follow API RP 7G and the connection drawing.
Length Ranges R1, R2 and R3
API 5DP groups delivered joint lengths into three ranges (Table C.3), each with order-tolerance rules - the share of the order allowed outside the band and a minimum length per joint. Range 2 is the workhorse length for most rotary rigs; Range 3 reduces the number of connections to make up on deep wells but needs tall masts and extended transport.
| Range | Length (API 5DP) | Metric | Typical use |
|---|---|---|---|
| R1 | 20-23 ft | 6.10-7.01 m | Shallow rigs, limited handling height |
| R2 | 29-32 ft | 8.84-9.75 m | Most common; standard stands and transport |
| R3 | 40-45 ft | 12.19-13.72 m | Deep wells; fewer connections per stand |
An edition caveat matters here: much of the older literature - and many legacy catalogues - still quotes 18-22 ft / 27-30 ft / 38-45 ft for R1/R2/R3. Those are the pre-5DP values; the current API 5DP bands are the ones above. Because the two conventions differ by up to 2 ft per joint, a purchase order should state the range code, the numeric band and the standard edition, and the tally should be checked joint by joint on delivery.
Tool Joints, Friction Welding and Weld-Zone Control
The tool joints carry their own API 5DP tensile requirements, separate from the pipe body. For Grades E, X, G, S and V the tool joint requires a minimum yield of 120,000 psi (827 MPa), a minimum tensile of 140,000 psi (965 MPa) and a minimum elongation of 13%; the sour-service SS tool joints run 110,000-125,000 psi yield with 15% minimum elongation. Tool joint material hardness is 285-341 HBW. That band is not an S-135 pipe body acceptance requirement.
The tool joints are joined to the upset pipe ends by friction welding, and the weld zone is then locally heat treated, hardness-tested and non-destructively examined. Field failures cluster at the weld zone, the upset transition and the thread shoulder rather than in the plain body, which is why the standard's weld-zone hardness limit (37 HRC maximum for Grades E, X, G and S) and the thread gauging records matter as much as the grade name. Recommended inspection points on a new order include dimensional and wall-thickness checks, full-length or agreed-coverage ultrasonic testing of the body, magnetic particle inspection of tool joints and thread roots, 100% drift verification, and thread inspection reports against the API 7-2 connection drawing.
Two order-specified options extend service life and are not part of the base grade requirements: internal coatings (for example the TK-34 family) reduce corrosion and friction loss inside the bore, and tool-joint hardbanding (for example ARNCO or ARMACOR, specified casing-friendly where required) controls tool-joint wear and protects casing during rotation. Specify coating type and thickness, holiday testing, hardbanding grade, width and repair criteria when they are wanted.
PSL Levels, Inspection and Documentation
API 5DP organises quality requirements into product specification levels. PSL-1 is the baseline covering dimensions, tensile properties and basic impact testing. PSL-2 adds mandatory Charpy testing with tighter dimensional tolerances and additional non-destructive examination. PSL-3 adds the further tests specified in API 5DP and permits third-party witnessing. The purchaser selects the level; the sour-service SS grades are handled through their own dedicated requirements instead of the PSL ladder.
Testing is performed per heat and lot with frequencies defined in the standard, and every pipe carries a continuous marking chain - size, weight, grade, upset type, connection, range, heat number, lot number and the "API 5DP" designation with the monogram where applicable. The document package should include the mill test certificate (EN 10204 3.1, or 3.2 with third-party cosignature where the project requires it), dimensional report, NDT report, thread inspection report, hardness records and coating or hardbanding records. For used drill string elements, reclassification and inspection follow API RP 7G-2 rather than the manufacturing specification.
Applications and Service Limits
S-135 drill pipe is selected where the drilling programme needs more tensile capacity, more torque margin and better fatigue control than G105 provides: deep and ultra-deep vertical wells, extended-reach and long horizontal sections, high-angle directional wells, and intervals with heavy mud or high rotary torque. In these wells the pipe sees repeated bending near build sections, high surface torque, high tensile loads while tripping and connection make-up stress, so the string design - not the grade name alone - decides the actual margin.
The one service limit buyers most often get wrong is hydrogen sulfide. Standard S-135 is not resistant to sulfide stress cracking: its strength band sits above the hardness limits applied to H2S service, and the failure mode is brittle with no ductile warning. For sour environments API 5DP provides the SS75, SS95 and SS105 grades with capped yield strength and hardness, tighter phosphorus and sulfur limits, used together with ISO 15156 / NACE MR0175. Names like "S135G" or "S135S" on marketing pages are not API 5DP grades.
Finally, all "how much pressure, torque or load" figures - collapse, burst, internal yield, torsional yield - are design calculations made with the formulas and coefficients of API RP 7G and API 5C3 (ISO 10400) for a specific size, weight and wall. They are not catalogue ratings of the grade, and no single number applies to every S-135 joint.
How S-135 Drill Pipe Differs from HWDP, Drill Collars and Geological Drill Rods
"Drill pipe" is often used loosely for several different drill-string products. Standard drill pipe (this page) is the thin-wall, Grade E-to-S pipe body with welded tool joints that makes up most of the drill string. Heavy weight drill pipe (HWDP) has a much thicker wall and a heavier centre upset, with a 55 ksi minimum-yield body, and is commonly manufactured to API Spec 7-1 rather than API 5DP; it transitions between the drill pipe and the drill collars. Drill collars are thick-walled, usually spiral or slick BHA components also covered by API 7-1, and pup joints are short drill pipe lengths used to adjust string spacing.
Geological and coal-mine drilling use their own rod families - designations such as R780, DZ40 or DZ50 with smaller diameters and different standards - and water-well or DTH drilling uses drill rods and DTH pipes that are not API 5DP products either. If an inquiry mixes these families, the connection, upset and mechanical expectations will not match; tell us the rig type and well design and we will confirm the correct product before quoting.
Ordering Information
S-135 drill pipe should be purchased by complete technical description, not by grade alone. A complete enquiry specifies: OD and nominal weight (or wall thickness); grade; length range (R1, R2 or R3); upset type (IU, EU or IEU); connection (for example NC50); product specification level (PSL-1, PSL-2 or PSL-3); optional internal coating and hardbanding; and the document package required (MTC to EN 10204 3.1 or 3.2, NDT, thread inspection, hardness records). A typical designation reads: 5 in. 19.50 lb/ft S-135 R2 IEU NC50, PSL-2.
Send us the well programme or the string design - depth, mud weight, planned torque and the existing string connections - and we will confirm size, grade, connection and inspection scope, then quote with the matching document package. For adjacent alloy tubulars, see the alloy steel pipe range.
Common Questions about API Spec 5DP S-135 Drill Pipe
Is "S-135" the same as "Grade S" in API 5DP?
Yes. The letter is the strength group and the number is the specified minimum yield strength in thousands of psi: S-135 means 135,000 psi (931 MPa) minimum yield, 165,000 psi maximum and 145,000 psi (1000 MPa) minimum tensile. A letter grade always carries the same minimum tensile value, so "S-105" or "G-95" are not real grades.
Why do data sheets disagree about impact energy and hardness for S-135?
Both depend on where and how they are measured. The API 5DP PSL-1 body requirement is 54 J (40 ft-lbf) average and 47 J single at 21 +/-3 deg C; 100 J / 80 J applies at PSL-3 (-20 deg C). The often-quoted "80 J / 65 J" pair matches subsize-specimen or other-specification rows, not the PSL-1 body values. On hardness, the standard controls the weld zone (37 HRC maximum) and caps the body only for SS grades; "HRC 28-36" is not an S-135 pipe body requirement.
Are Range 2 joints 27-30 ft or 29-32 ft?
API Spec 5DP (2nd Edition) defines R1 as 20-23 ft, R2 as 29-32 ft and R3 as 40-45 ft. The shorter bands come from pre-5DP literature and are still widely copied. State the range code and the edition on the order and check the tally on delivery.
Can S-135 drill pipe be used in hydrogen sulfide (sour) service?
No. Standard S-135 is not resistant to sulfide stress cracking. Sour service uses the API 5DP SS75/SS95/SS105 grades with capped yield and hardness plus ISO 15156 / NACE MR0175; "S135G" or "S135S" are not API designations.
What does a complete S-135 order designation look like?
For example: 5 in. 19.50 lb/ft S-135 R2 IEU NC50, PSL-2, with TK-34 internal coating, ARNCO 300XT hardbanding and EN 10204 3.2 certification. Grade plus size alone leaves connection, upset, length class and inspection scope open - each of those changes the product delivered.