ASTM A179, A213 and A249 are three different heat exchanger tube specifications. A179 is seamless cold-drawn low-carbon steel. A213 is seamless ferritic alloy and austenitic stainless tube for boiler, superheater and heat-exchanger service. A249 is welded austenitic stainless tube. Picking one by temperature or price, without the grade and the wall basis, orders the wrong tube. Pipe ordered by nominal size and schedule is a different product.
What the Three Specifications Cover
Heat exchanger tube is ordered by outside diameter and wall, not as a pipe schedule. The wall has to carry the pressure difference between the tube side and the shell side, and the bore has to stay clean enough for the duty. A179, A213 and A249 answer different material and process questions. They do not overlap just because all three can go into a shell-and-tube exchanger.
| Item | ASTM A179 | ASTM A213 | ASTM A249 |
|---|---|---|---|
| Route | Seamless, cold-drawn | Seamless | Welded, then cold worked |
| Material | Low-carbon steel | Ferritic alloy and austenitic stainless | Austenitic stainless |
| Condition | Heat treated as the standard requires | Solution annealed for austenitic grades | Heat treated after welding |
| Confirm on the order | Outside diameter and wall | Grade, size and wall basis | Grade, weld test and wall basis |
ASTM A179
ASTM A179/A179M covers seamless cold-drawn low-carbon steel tubes for tubular heat exchangers, condensers and similar equipment. The chemistry and the wall limits belong to the edition named on the order. Do not copy a carbon range or a minimum wall from an undated table and treat it as the requirement. Cold drawing is how the tube gets its size and surface. After drawing, the tube is heat treated as that standard requires. Straight lengths and U-bends are both ordered forms. State which one, because a U-bend radius is a drawing item.
ASTM A213
ASTM A213 covers seamless ferritic and austenitic alloy-steel boiler, superheater and heat-exchanger tubes. The grades on a typical enquiry run from low-alloy T11 and T22 through T91, and the austenitic grades TP304, TP304L, TP316, TP316L, TP321 and TP347. The T prefix means tube. It is not the P pipe grade in ASTM A335. Austenitic tubes are furnished solution annealed. For the grades and tests quoted on a product page, see seamless ASTM A213 heat exchanger tubes in TP304 and TP316L. That page states the A213 size scope and the wall basis. Creep strength and a maximum service temperature depend on the grade and the design code. They are not one number shared by T11 and TP316.
ASTM A249
ASTM A249 covers welded austenitic stainless boiler, superheater, heat-exchanger and condenser tubes. Strip is formed and welded, then the tube is cold worked and heat treated so the weld is part of the tube rather than a left-on bead. It can be the right specification when the design allows a welded tube. It is not a seamless tube with a discount. The weld has to pass the nondestructive test the standard requires, and the grade still has to be named: TP304 and TP316L are not the same analysis.
Size, Wall and Tests
Give the outside diameter, the wall and whether the wall is minimum wall or average wall. Birmingham wire gauge is only a wall series. Quote the millimetre or inch thickness as well, and take the tolerance from the ordered edition. Tests that apply across these specifications include dimensions, a flattening test, a flaring test, and either a hydrostatic test or a nondestructive electric test. Eddy-current testing finds the defects that method can find. It does not replace the test the standard names. The alloy steel pipe range is the pipe form of related grades, and carbon steel pipe is not an A179 tube.
What to Confirm Before Ordering
Name the specification and edition, the grade, seamless or welded, outside diameter, wall thickness, wall basis, straight or U-bend, and the tests and certificate. A temperature band or a percent saving is not a way to choose among A179, A213 and A249.