Product Description
Carbon steel boiler tubes are small-diameter tubes for the heating surface of a boiler: waterwalls, generating tubes and economizers. This page covers three carbon steel specifications only. ASTM A192/A192M (ASME SA-192) is a single-grade seamless tube. ASTM A210/A210M (ASME SA-210) is a seamless medium-carbon tube in Grade A-1 and Grade C, used when the allowable-stress calculation needs a higher minimum tensile strength than A192. ASTM A178/A178M (ASME SA-178) is an electric-resistance-welded tube in Grades A, C and D. It is not a seamless tube.
Alloy boiler tubes such as ASTM A213 T11, T22 and T91, and stainless tubes such as 304 and 316, are different products. They are not grades of the carbon steel boiler tube on this page, and their chemistry and strength are not offered here. For line pipe and process pipe, compare the Carbon Steel Pipe range before you fix the product form.
Ordering Summary
The table below is an ordering summary. The specification block above this article already lists the same order fields. The regular range is 10 mm to 219 mm outside diameter, 2 mm to 20 mm wall, and 3 m to 12 m long. A size or length outside that range is made to the ordered dimensions.
| Item | Ordering basis |
|---|---|
| Product | Carbon steel boiler and superheater tubes |
| Seamless | ASTM A192/A192M; ASTM A210/A210M Grade A-1 or Grade C |
| Electric-resistance-welded | ASTM A178/A178M Grade A, C or D |
| ASME boiler parts | Name SA-192, SA-210 or SA-178 on the order when the boiler code requires the SA designation |
| Size | 10 mm to 219 mm outside diameter, wall 2 mm to 20 mm. Other sizes are made to the ordered dimensions. |
| Length | 3 m to 12 m, fixed or random. Other lengths are made to the ordered length. |
| Condition | Hot-finished or cold-drawn for A192 and A210; normalized, or normalized or stress-relieved, for A178 |
| Documents | Mill test certificate. Third-party inspection only if the order names it |
Carbon Steel Boiler Tube Grades
A192 is one grade. A210 has two grades, and the grade letter changes the minimum tensile strength. A178 has three grades, and Grade A of A178 is not the same tube as Grade A-1 of A210. Read the standard number and the grade together.
| Standard and grade | Product form | Where it is used |
|---|---|---|
| ASTM A192 / SA-192 | Seamless, single grade | High-pressure carbon steel boiler tubes, waterwalls and generating tubes, where 325 MPa minimum tensile is enough |
| ASTM A210 Grade A-1 / SA-210 A-1 | Seamless | Boiler and economizer tubes when the design needs 415 MPa minimum tensile |
| ASTM A210 Grade C / SA-210 C | Seamless | Higher-pressure carbon steel boiler tubes, 485 MPa minimum tensile |
| ASTM A178 Grade A / SA-178 A | Electric-resistance-welded | Boiler and superheater tubes where a welded carbon steel tube is specified |
| ASTM A178 Grade C / SA-178 C | Electric-resistance-welded | Medium-carbon ERW boiler tubes, 415 MPa minimum tensile |
| ASTM A178 Grade D / SA-178 D | Electric-resistance-welded | Carbon-manganese ERW boiler tubes, 485 MPa minimum tensile |
Chemical Composition
The ranges below are reference values taken from published compilations of ASTM A192/A192M, A210/A210M and A178/A178M. They are not a certificate for a heat, and the purchase order controls the edition. Silicon and residual limits that were not consistent across the sources checked for this page are left off the table.
| Grade | C | Mn | P max | S max |
|---|---|---|---|---|
| A192 | 0.06-0.18 | 0.27-0.63 | 0.035 | 0.035 |
| A210 Grade A-1 | 0.27 max | 0.93 max | per standard | per standard |
| A210 Grade C | 0.35 max | 0.29-1.06 | per standard | per standard |
| A178 Grade A | 0.06-0.18 | 0.27-0.63 | 0.035 | 0.035 |
| A178 Grade C | 0.35 max | 0.80 max | 0.035 | 0.035 |
| A178 Grade D | 0.27 max | 1.00-1.50 | 0.030 | 0.015 |
A192 also limits silicon to 0.25% maximum in the compilations checked. A178 Grade D requires silicon at 0.10% minimum in the compilation whose table is used here. One supplier page lists Grade D manganese as 0.80-1.20%. That page also mis-states the A178 tensile minimums, so its chemistry is not used. Do not copy the A192 carbon range onto A210 Grade C: Grade C allows up to 0.35% carbon, and A210 Grade A-1 is 0.27% maximum, not 0.35%.
Mechanical Properties
Values are minimums from the same reference compilations, in MPa with the ksi figure from the source. They apply to the grade named in the row. They are not a strength for every carbon steel boiler tube, and they are not an allowable stress.
| Grade | Tensile min | Yield min | Elongation min in 50 mm |
|---|---|---|---|
| A192 | 325 MPa (47 ksi) | 180 MPa (26 ksi) | 35% |
| A210 Grade A-1 | 415 MPa (60 ksi) | 255 MPa (37 ksi) | See the ordered edition |
| A210 Grade C | 485 MPa (70 ksi) | 275 MPa (40 ksi) | See the ordered edition |
| A178 Grade A | 325 MPa (47 ksi) | 180 MPa (26 ksi) | 35% |
| A178 Grade C | 415 MPa (60 ksi) | 255 MPa (37 ksi) | 30% |
| A178 Grade D | 485 MPa (70 ksi) | 275 MPa (40 ksi) | 30% |
A178 reduces the elongation minimum as the wall becomes thinner than 8 mm (5/16 in). A figure of 30% for every grade, or 35% for every grade, is wrong. A210 elongation is omitted here because the sources checked for this page did not agree on a single published minimum. One supplier data sheet also assigns A210 tensile numbers to A178 Grade A and Grade D; those figures are not used. The minimum tensile strength of A178 Grade A is 325 MPa, not 380 MPa, and Grade D is 485 MPa, not 415 MPa.
Seamless and Welded Carbon Steel Boiler Tubes
Seamless and welded are different products on this page, not two finishes of one tube. A192 and A210 are seamless: hot-finished, or cold-drawn and heat-treated as the standard requires. A178 is made by electric-resistance welding from steel strip. Ordering "seamless A178" or "welded A192" mixes two standards.
The weld in an A178 tube is part of the pressure boundary. Heat treatment is mandatory under that specification: full-body normalizing for Grades A and C, and normalizing or stress relieving for Grade D. Do not treat a welded carbon steel boiler tube as interchangeable with a seamless tube of a similar carbon content unless the boiler design and the purchase specification allow A178.
Dimensions and Wall Thickness
Order carbon steel boiler tubes by outside diameter and minimum wall thickness. Pipe schedule is a piping convention. A schedule number does not state the minimum wall a boiler calculation uses, and a tube described only as Schedule 40 or Schedule 80 can miss the wall the design needs at temperature.
The regular supply is 10 mm to 219 mm outside diameter, 2 mm to 20 mm wall, and 3 m to 12 m. Order by outside diameter and minimum wall, not by pipe schedule. A size or length outside that range is made to the ordered dimensions.
Material Characteristics
A192 keeps carbon low, at 0.06-0.18%, which is why its minimum tensile strength is 325 MPa and its elongation minimum is high. A210 raises carbon, to 0.27% maximum in Grade A-1 and 0.35% maximum in Grade C, and the minimum tensile strength rises to 415 MPa and 485 MPa. That is a strength choice for the wall-thickness calculation. It is not a corrosion upgrade.
Carbon steel boiler tubes are not a corrosion-resistant product. They oxidize in steam and flue gas, and the useful temperature is set by the allowable stress in the boiler code for the grade, the pressure and the tube geometry. This page does not publish a maximum service temperature. Figures such as 450 °C for all carbon steel, 650 °C, or 800 °C belong to other alloys or to a specific design case, and they are not a rating for A192, A210 or A178.
Allowable stress, creep and the decision between A192 and A210 belong in the boiler design, using the SA designation and the stress tables required by the code. A higher grade number is not automatically the correct tube.
Applications
Typical uses for these carbon steel grades are boiler waterwall tubes, generating tubes and economizer tubes in industrial and utility boilers, where the design temperature stays inside the carbon steel range. A178 is also specified for welded boiler and superheater tubes when the purchase specification allows electric-resistance-welded tube.
Superheater and reheater tubing at higher temperature is commonly an alloy grade under ASTM A213, such as T11, T22 or T91, or a stainless grade. Those tubes are outside this product. So are headers and main steam pipe under ASTM A335, which is a pipe specification, not a boiler tube specification. Marine, aerospace and chemical-corrosion claims are not uses we state for carbon steel boiler tubes.
Ordering Information
A usable inquiry names the standard and grade, the outside diameter, the minimum wall, the length, the quantity, and whether the tube is seamless or electric-resistance-welded. Add the end finish, the heat-treatment condition if you need a specific one, and the tests the order must include: tensile, flattening or flaring as the standard requires, and hydrostatic testing or a nondestructive electric test where the standard allows either.
If the tube is a boiler code pressure part, write SA-192, SA-210 or SA-178 on the order rather than only the ASTM number. Name a third-party inspector only when you require one. A mill test certificate with heat number, chemistry and mechanical results is the normal document; it is not a promise of a named inspection agency, a stock length, or a delivery time.
Frequently Asked Questions
Which carbon steel boiler tube standard should the order name?
Name ASTM A192 when a single-grade seamless carbon steel boiler tube is enough. Name ASTM A210 Grade A-1 or Grade C when the allowable-stress calculation needs a higher minimum tensile strength than A192. Name ASTM A178 Grade A, C or D only when an electric-resistance-welded tube is acceptable. For an ASME boiler pressure part, name the SA counterpart on the order.
Is ASTM A178 a seamless boiler tube?
No. ASTM A178/A178M covers electric-resistance-welded carbon steel and carbon-manganese steel boiler and superheater tubes. The seamless carbon steel boiler tubes on this page are ASTM A192 and ASTM A210. State the product form on the inquiry so the two are not quoted as one tube.
Why were SA-213 T22, T91 and 304/316 removed from this page?
Those are not carbon steel boiler tubes. SA-213 T11, T22 and T91 are alloy steel tubes, and 304 and 316 are stainless steels. Listing their chemistry and strength here made a carbon steel order look as if it included alloy and stainless grades. Ask for those grades as separate products.
Can boiler tubes be ordered by pipe schedule?
Not by schedule alone. Carbon steel boiler tubes are ordered by outside diameter and minimum wall thickness. A schedule number does not state the minimum wall the boiler calculation uses. Send the outside diameter, the minimum wall, the length and the standard.
What should a quotation request include?
Send the standard and grade, outside diameter, minimum wall, length, quantity, seamless or ERW, end finish, and whether a hydrostatic test, nondestructive test, or a named third-party inspection is required. Service temperature and pressure belong in the design calculation. This page does not publish an allowable temperature or pressure.